SF 321A
Art. no. 101596
Flow sensor with ATEX certification Group II Category 2G
Housing made of V4A. Connection to separate
evaluation electronics. Device designation Ex II
2 G EEx ia IIC T4 Based on the calorimetric
principle, the flow sensor can be used for
monitoring liquid and gaseous media.
Pressure-resistant up to 30 bar. Protection
class: IP 67. Temperature class T4, 6 m
connection cable TPE-S,5 x 0.34 mm² Media
temperature: -26 °C – +80 °C Measuring range: 2 –
20 m/s thread G1/2 A ATEX test certification: DMT
03 ATEX E091
Data sheet no. 12101
Housing made of V4A. Connection to separate
evaluation electronics. Device designation Ex II
2 G EEx ia IIC T4 Based on the calorimetric
principle, the flow sensor can be used for
monitoring liquid and gaseous media.
Pressure-resistant up to 30 bar. Protection
class: IP 67. Temperature class T4, 6 m
connection cable TPE-S,5 x 0.34 mm² Media
temperature: -26 °C – +80 °C Measuring range: 2 –
20 m/s thread G1/2 A ATEX test certification: DMT
03 ATEX E091
Data sheet no. 12101
Unit price
€420.30
Flow sensor with ATEX certification Group II Category 2G
Housing made of V4A. Connection to separate
evaluation electronics. Device designation Ex II
2 G EEx ia IIC T4 Based on the calorimetric
principle, the flow sensor can be used for
monitoring liquid and gaseous media.
Pressure-resistant up to 30 bar. Protection
class: IP 67. Temperature class T4, 6 m
connection cable TPE-S,5 x 0.34 mm² Media
temperature: -26 °C – +80 °C Measuring range: 2 –
20 m/s thread G1/2 A ATEX test certification: DMT
03 ATEX E091
Data sheet no. 12101
Housing made of V4A. Connection to separate
evaluation electronics. Device designation Ex II
2 G EEx ia IIC T4 Based on the calorimetric
principle, the flow sensor can be used for
monitoring liquid and gaseous media.
Pressure-resistant up to 30 bar. Protection
class: IP 67. Temperature class T4, 6 m
connection cable TPE-S,5 x 0.34 mm² Media
temperature: -26 °C – +80 °C Measuring range: 2 –
20 m/s thread G1/2 A ATEX test certification: DMT
03 ATEX E091
Data sheet no. 12101
Measured medium 1: |
Fluid or gaseous media |
---|---|
Measuring range 1: |
3...300 cm/s (fluid) / 200...2000 cm/s (gas) (switchable) |
Outputs 1: |
Measurement signal |
Permissible temperature of medium 1: |
-20...+70 °C |
Permits / approvals : |
ATEX |
Protection type: |
IP67 |
Technical data
Measured medium 1: |
Fluid or gaseous media |
---|---|
Measuring range 1: |
3...300 cm/s (fluid) / 200...2000 cm/s (gas) (switchable) |
Outputs 1: |
Measurement signal |
Permissible temperature of medium 1: |
-20...+70 °C |
Permits / approvals : |
ATEX |
Protection type: |
IP67 |