H-T-I-150-D-NFC
Art. no. 105153
Duct humidity sensor with display and NFC interface 1 outputs 0 – 10 V, 4 – 20 mA switchable
For measurement of relative humidity in
ventilation ducts. Measuring range, humidity: 0 –
100% rH. Tolerance humidity: +/- 3% rH at 25 °C
and 20 – 80% rH Offsets adjustable via rotary
switch, 8 lid positions selectable. 5-point
calibration and parameterization via the NFC
interface on the display. Incl. adjustable
mounting flange F-10. Output signal linear due to
microprocessor technology. Supply voltage 15 – 30
V AC/DC. Power consumption: 105 mA (24 V AC)/35
mA (24 V DC). Sensor diameter 10 mm, sensor
length 150 mm. Housing: Base: PBT, color similar
to RAL 7016. Display: PC, transparent. Ring: PBT,
color similar to RAL 1003. IP 65 protection
(including seal ring). Strain relief M16. Fast
wiring with spring terminals 0.2 – 1.5 mm².
Leakage resistance: 100 MΩ, 20°C, 500 V DC.
Permissible ambient conditions: -20 °C to 70 °C.
0 – 95% rH (non-condensing).
Data sheet no. 20916
For measurement of relative humidity in
ventilation ducts. Measuring range, humidity: 0 –
100% rH. Tolerance humidity: +/- 3% rH at 25 °C
and 20 – 80% rH Offsets adjustable via rotary
switch, 8 lid positions selectable. 5-point
calibration and parameterization via the NFC
interface on the display. Incl. adjustable
mounting flange F-10. Output signal linear due to
microprocessor technology. Supply voltage 15 – 30
V AC/DC. Power consumption: 105 mA (24 V AC)/35
mA (24 V DC). Sensor diameter 10 mm, sensor
length 150 mm. Housing: Base: PBT, color similar
to RAL 7016. Display: PC, transparent. Ring: PBT,
color similar to RAL 1003. IP 65 protection
(including seal ring). Strain relief M16. Fast
wiring with spring terminals 0.2 – 1.5 mm².
Leakage resistance: 100 MΩ, 20°C, 500 V DC.
Permissible ambient conditions: -20 °C to 70 °C.
0 – 95% rH (non-condensing).
Data sheet no. 20916
Unit price
€243.30
Duct humidity sensor with display and NFC interface 1 outputs 0 – 10 V, 4 – 20 mA switchable
For measurement of relative humidity in
ventilation ducts. Measuring range, humidity: 0 –
100% rH. Tolerance humidity: +/- 3% rH at 25 °C
and 20 – 80% rH Offsets adjustable via rotary
switch, 8 lid positions selectable. 5-point
calibration and parameterization via the NFC
interface on the display. Incl. adjustable
mounting flange F-10. Output signal linear due to
microprocessor technology. Supply voltage 15 – 30
V AC/DC. Power consumption: 105 mA (24 V AC)/35
mA (24 V DC). Sensor diameter 10 mm, sensor
length 150 mm. Housing: Base: PBT, color similar
to RAL 7016. Display: PC, transparent. Ring: PBT,
color similar to RAL 1003. IP 65 protection
(including seal ring). Strain relief M16. Fast
wiring with spring terminals 0.2 – 1.5 mm².
Leakage resistance: 100 MΩ, 20°C, 500 V DC.
Permissible ambient conditions: -20 °C to 70 °C.
0 – 95% rH (non-condensing).
Data sheet no. 20916
For measurement of relative humidity in
ventilation ducts. Measuring range, humidity: 0 –
100% rH. Tolerance humidity: +/- 3% rH at 25 °C
and 20 – 80% rH Offsets adjustable via rotary
switch, 8 lid positions selectable. 5-point
calibration and parameterization via the NFC
interface on the display. Incl. adjustable
mounting flange F-10. Output signal linear due to
microprocessor technology. Supply voltage 15 – 30
V AC/DC. Power consumption: 105 mA (24 V AC)/35
mA (24 V DC). Sensor diameter 10 mm, sensor
length 150 mm. Housing: Base: PBT, color similar
to RAL 7016. Display: PC, transparent. Ring: PBT,
color similar to RAL 1003. IP 65 protection
(including seal ring). Strain relief M16. Fast
wiring with spring terminals 0.2 – 1.5 mm².
Leakage resistance: 100 MΩ, 20°C, 500 V DC.
Permissible ambient conditions: -20 °C to 70 °C.
0 – 95% rH (non-condensing).
Data sheet no. 20916
Interface 1: |
NFC |
---|---|
Measured medium 1: |
Air |
Measuring range 1: |
0...100 %rh |
Outputs 1: |
Measurement signal 0... 10 V / 4...20 mA (switchable) |
Permissible temperature of medium 1: |
-40...+100 °C |
Power supply 1: |
24 V AC/DC |
Protection type: |
IP65 |
Sensor element 1: |
Digital humidity sensor |
Technical data
Interface 1: |
NFC |
---|---|
Measured medium 1: |
Air |
Measuring range 1: |
0...100 %rh |
Outputs 1: |
Measurement signal 0... 10 V / 4...20 mA (switchable) |
Permissible temperature of medium 1: |
-40...+100 °C |
Power supply 1: |
24 V AC/DC |
Protection type: |
IP65 |
Sensor element 1: |
Digital humidity sensor |