Technical data

Inputs 1:
Sensor input
Inputs 2:
Reset
Measuring range 1:
100...6000 rpm
Outputs 1:
Switching output
Outputs 2:
Analog output 0...10 V
Permissible ambient conditions:
0…+40 °C
Protection type:
IP40
Sensor element 1:
External proximity switch
image

Downloads

Datasheet 10102 - Electronic V-belt monitoring device EKW 2.3.x.x / EKW 2.3.x.xA
Catalogue 2024 (PDF)
Catalogue price list 2024 (Excel)
Catalogue price list 2024 (PDF)
Flip catalogue 2024
EG-Konformität_EKW_2016-04-20 (only German)

Accessories

HWK

Mounting bracket and tubular tape
Complete for mounting on very small fans, up to
approx. 1.5 kW
Data sheet no. 10501
HWN

Mounting bracket and tubular tape
Complete for mounting on small and medium fans, up
to approx. 7 kW
Data sheet no. 10501
HWL

Mounting bracket and tubular tape
Complete for mounting on large fans, up to approx.
22 kW
Data sheet no. 10501
HWS

Mounting bracket and tubular tape
Complete for mounting on very large fans, from
approx. 22kW
Data sheet no. 10501
SN-Z3

Two-wire sensor, shielded, D = 18 mm, L = 40 mm
For detecting the rotation of fans, with a 2 m
cable, IP 67 protection, switching status display
with LED, contactless output, transistor with a
max. switching distance of 8 mm, ambient
temperature -25 °C – +75 °C,
Data sheet no. 10501
NAMUR

Ex sensor D = 18 mm, L = 30 mm/BI5-G18-Y1
With 2 m cable, only in connection with EX
switching amplifier IM1-12Ex-T.
Data sheet no. 10501
SNSA

Sensor, shielded, D = 18 mm, L = 40 mm.
""for detecting the rotation of fans, with a 2 m
cable, IP 67 protection.
SNLA

Sensor D = 18 mm, L = 60 mm
""for detecting the rotation of fans, with a 2 m
cable, IP 67 protection.
IM1-12EX-T

EX switching amplifier universal current, with ATEX certification
Together with a Namur sensor for using the
electronic v-belt monitor in the EX area, zone 2.
Single-channel version. Intrinsically safe
control circuit with wire breakage and
short-circuit monitoring. In case of error, all
outputs are switched off. The EX switching
amplifier with transistor output is
interconnected between the Namur sensor and the
electronic V-belt monitor. LED with two colors to
visualize the switching state (yellow) and the
fault (red). Green LED to indicate the operating
state. Supply voltage: 20 – 250 V AC/20 – 125 V
DC (40 – 70 Hz) Power consumption: < 3 W
switching voltage: < 30 VDC switching current: <
50 mA Protection class: IP 20 Dimensions: 18 x
104 x 110 mm (W x H x D) Areas of application:
[Exia] IIC/IIB and Ex nA nC [nL] IIC/IIB T4.
Ex-certification in accordance with Conf.
certificate: TÜV 04 ATEX 2553
Data sheet no. 10162

Einblicke zu 40 Jahren Oppermann

Geschäftsführung Heike Dirmeier

Dauer 4 Minuten

Interview Heike Dirmeier, Matthias Fricke

Dauer 12 Minuten
Contact us
Fields marked with asterisks (*) are required.
Head office

Do you have questions about our products or need advice? Please do not hesitate to contact us.