GMF 5.IR.R410a.12.MOD
Art. no. 103547
Freon R410a gas measuring sensor, measuring range 0 – 2,000 ppm, bus-compatible
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -20 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting on the floor.
Relative gas density: >2.0.
Data sheet no. 38110
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -20 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting on the floor.
Relative gas density: >2.0.
Data sheet no. 38110
Unit price
€1,750.00
Freon R410a gas measuring sensor, measuring range 0 – 2,000 ppm, bus-compatible
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -20 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting on the floor.
Relative gas density: >2.0.
Data sheet no. 38110
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -20 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting on the floor.
Relative gas density: >2.0.
Data sheet no. 38110
Interface 1: |
Modbus |
---|---|
Permissible temperature of medium 1: |
-20…+40 °C |
Power supply 1: |
24 VDC |
Protection type: |
IP54 |
Sensor element 1: |
Infrared (NDIR) |
Technical data
Interface 1: |
Modbus |
---|---|
Permissible temperature of medium 1: |
-20…+40 °C |
Power supply 1: |
24 VDC |
Protection type: |
IP54 |
Sensor element 1: |
Infrared (NDIR) |
Downloads