GMF 4.Z.O2.54.MOD
Art. no. 104181
Oxygen gas measuring sensor. Measuring range 0 – 25 vol%, bus-compatible.
OPP-SOR gas measuring sensor in an aluminum
housing. For measuring oxygen (O2). The sensor
can only be used to measure oxygen
displacement. Measuring principle: Zirconium
oxide sensor. Temperature compensated to provide
high accuracy and low cross-sensitivity to other
gases. Gas inlet by diffusion via sinter filter.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Permissible
humidity 0 to 95 % rH, non-condensing.
Dimensions: 125 x 80 x 57 mm (L x W x D), color
gray, protection class: IP 44. Mounting height:
1.5 – 1.8m. Relative gas density 1.0.
Data sheet no. 38112
OPP-SOR gas measuring sensor in an aluminum
housing. For measuring oxygen (O2). The sensor
can only be used to measure oxygen
displacement. Measuring principle: Zirconium
oxide sensor. Temperature compensated to provide
high accuracy and low cross-sensitivity to other
gases. Gas inlet by diffusion via sinter filter.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Permissible
humidity 0 to 95 % rH, non-condensing.
Dimensions: 125 x 80 x 57 mm (L x W x D), color
gray, protection class: IP 44. Mounting height:
1.5 – 1.8m. Relative gas density 1.0.
Data sheet no. 38112
Unit price
€1,253.60
Oxygen gas measuring sensor. Measuring range 0 – 25 vol%, bus-compatible.
OPP-SOR gas measuring sensor in an aluminum
housing. For measuring oxygen (O2). The sensor
can only be used to measure oxygen
displacement. Measuring principle: Zirconium
oxide sensor. Temperature compensated to provide
high accuracy and low cross-sensitivity to other
gases. Gas inlet by diffusion via sinter filter.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Permissible
humidity 0 to 95 % rH, non-condensing.
Dimensions: 125 x 80 x 57 mm (L x W x D), color
gray, protection class: IP 44. Mounting height:
1.5 – 1.8m. Relative gas density 1.0.
Data sheet no. 38112
OPP-SOR gas measuring sensor in an aluminum
housing. For measuring oxygen (O2). The sensor
can only be used to measure oxygen
displacement. Measuring principle: Zirconium
oxide sensor. Temperature compensated to provide
high accuracy and low cross-sensitivity to other
gases. Gas inlet by diffusion via sinter filter.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Permissible
humidity 0 to 95 % rH, non-condensing.
Dimensions: 125 x 80 x 57 mm (L x W x D), color
gray, protection class: IP 44. Mounting height:
1.5 – 1.8m. Relative gas density 1.0.
Data sheet no. 38112
Outputs 1: |
4...20 mA |
---|---|
Permissible temperature of medium 1: |
-10...+40 °C |
Power supply 1: |
24 VDC |
Protection type: |
IP54 |
Technical data
Outputs 1: |
4...20 mA |
---|---|
Permissible temperature of medium 1: |
-10...+40 °C |
Power supply 1: |
24 VDC |
Protection type: |
IP54 |
Downloads