ST-P-DA-STB
Art. no. 101650
Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. A green LED indicates
contamination (service), a red LED indicates an
alarm. The sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VDS test
certificate: G 202091
Data sheet no. 40101
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. A green LED indicates
contamination (service), a red LED indicates an
alarm. The sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VDS test
certificate: G 202091
Data sheet no. 40101
Unit price
€231.50
Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. A green LED indicates
contamination (service), a red LED indicates an
alarm. The sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VDS test
certificate: G 202091
Data sheet no. 40101
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. A green LED indicates
contamination (service), a red LED indicates an
alarm. The sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VDS test
certificate: G 202091
Data sheet no. 40101
Measured medium 1: |
Air |
---|---|
Permissible temperature of medium 1: |
-10…+50 °C |
Permits / approvals : |
VdS |
Power supply 1: |
16...30 V DC |
Sensor element 1: |
Diffused light |
Technical data
Measured medium 1: |
Air |
---|---|
Permissible temperature of medium 1: |
-10…+50 °C |
Permits / approvals : |
VdS |
Power supply 1: |
16...30 V DC |
Sensor element 1: |
Diffused light |
Einblicke zu 40 Jahren Oppermann