DRM SOC-E3N-YBO
Art. no. 104724
Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. Relay
contact, loadable with 24V/1A power supply 12 –
30 V DC. Ambient temperature: -10 – +50 °C VdS
test certificate: G 217088
Data sheet no. 40202
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. Relay
contact, loadable with 24V/1A power supply 12 –
30 V DC. Ambient temperature: -10 – +50 °C VdS
test certificate: G 217088
Data sheet no. 40202
Unit price
€233.80
Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. Relay
contact, loadable with 24V/1A power supply 12 –
30 V DC. Ambient temperature: -10 – +50 °C VdS
test certificate: G 217088
Data sheet no. 40202
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. Relay
contact, loadable with 24V/1A power supply 12 –
30 V DC. Ambient temperature: -10 – +50 °C VdS
test certificate: G 217088
Data sheet no. 40202
Measured medium 1: |
Air |
---|---|
Permissible temperature of medium 1: |
-10…+50 °C |
Permits / approvals : |
VdS |
Power supply 1: |
12...30 V DC |
Sensor element 1: |
Diffused light |
Technical data
Measured medium 1: |
Air |
---|---|
Permissible temperature of medium 1: |
-10…+50 °C |
Permits / approvals : |
VdS |
Power supply 1: |
12...30 V DC |
Sensor element 1: |
Diffused light |