Technical data

Outputs 1:
Relay outputs
Permissible temperature of medium 1:
0…+50 °C
image

Downloads

Datasheet 43102 - Control unit for smoke detector ABAV-S3
Catalogue 2024 (PDF)
Catalogue price list 2024 (Excel)
Catalogue price list 2024 (PDF)
Flip catalogue 2024

Accessories

DRM SOC-E3N-YBN

Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. The
sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VdS test
certificate: G 217088
Data sheet no. 40105
DRM SOC-E3N-YBO

Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. The red LED flashes in
the event of contamination (service) and is
permanently lit in the event of an alarm. Relay
contact, loadable with 24V/1A power supply 12 –
30 V DC. Ambient temperature: -10 – +50 °C VdS
test certificate: G 217088
Data sheet no. 40202
DRM DCD-AE3-YBN

Thermodifferential alarm including base
As fire detector for installation for ceiling
mounting. Responds to a fast temperature rise or
if a fixed temperature limit value is exceeded.
LED display and contact output via the ABAV-S
control unit. The fire detector is used where
smoke detectors would trigger false alarms due to
ambient conditions such as smoke, steam or dust.
The rate of temperature rise is defined according
to EN 54 class A1R. The upper temperature limit
is set to 57 ° C ± 3 C. The thermodifferential
alarm runs with the ABAV-S control unit which
also supplies the 24 V DC voltage. Alarm current
consumption 40 mA at 24 V DC Ambient temperature:
-10 – +50° C no icing Dimensions with base 100 x
38 mm (Ø x H)
Data sheet no. 43502
ST-P-DA-STB

Optical smoke detector for use in rooms for early detection of smoke
Detects smoldering fires and fires with smoke
development. The detector operates according to
the scattered light principle. Including mounting
base. Light transmitters and receivers are
arranged in the measuring chamber in such a way
that the luminous beam of the transmitter cannot
hit the receiver directly. Only the light which
is scattered by floating particles (Tyndall
effect) reaches the receiver and is converted
into an electrical signal. A green LED indicates
contamination (service), a red LED indicates an
alarm. The sensor is operated by the ABAV-S
(service-alarm-contact) control unit which also
supplies the 24 V DC voltage. Ambient
temperature: -10 – +50 °C VDS test
certificate: G 202091
Data sheet no. 40101
TD 122.3

Thermodifferential alarm 24 V DC including base
As fire detector for installation for ceiling
mounting. Responds to a fast temperature rise or
if a fixed temperature limit value is exceeded.
LED display and contact output via the ABAV-S
control unit. The fire detector is used where
smoke detectors would trigger false alarms due to
ambient conditions such as smoke, steam or dust.
The rate of temperature rise is defined according
to EN 54 class A1R. The upper temperature limit
value is set fixed to 57 °C ± 3 C. An output for
parallel display (-1.4 V/100 mA) is provided. The
thermodifferential alarm runs with the ABAV-S
control unit which also supplies the 24V DC
voltage. Alarm current consumption 52 mA at 24 V
DC Ambient temperature: -20 – 90 °C no icing.
Dimensions with base 100 x 50 mm (Ø x H)
Data sheet no. 43501