FT-MOD-I-200-D-NFC

Air flow

Air flow temperature transmitter with display and NFC interface Modbus output, L = 200 mm
For measurement of air flow and temperature in
ventilation ducts. Measuring range flow 0 – 20
m/s, temperature: 0 – 50 °C. 10x offset
adjustable via rotary switch. 8 lid positions
selectable. 5-point calibration and
parameterization (address, baud rate) via the NFC
interface on the display. Incl. adjustable
mounting flange F-10 for adjusting the immersion
depth (50 – 190 mm). Output signal linear due to
microprocessor technology. Supply voltage 15 – 30
V AC/DC. Power consumption: 205 mA (24 V AC)/70
mA (24 V DC). Sensor diameter 10 mm (stainless
steel). Housing: Base: PBT, color similar to RAL
7016. Display: PC, transparent. Ring: PBT, color
similar to RAL 1003. IP65 protection (incl. seal
ring). 2 x strain relief M16. Fast wiring with
double-row spring terminals. Cable cross-section
0.2 – 1.5 mm². Terminal resistance via DIP
switch. Leakage resistance: 100 MΩ, 20 °C, 500 V
DC. Permissible ambient conditions: -20 °C to
70°C. 0 – 95% rH (non-condensing).
Data sheet no. 11400
AT-050

Temperature

Stainless steel immersion sleeve Nominal pressure: PN 40 bar, material: 1.4571.
Screw-in thread: G 1/2 A Outer Ø: 9 mm
Installation length: 50 mm
ATM-050

Temperature

Brass immersion sleeve Nominal pressure: PN 16 bar.
Screw-in thread: G 1/2 A Outer Ø: 8 mm
Installation length: 50 mm
Befestigungswinkel für DD/DDS,

Air pressure

Metal, L-shape, type 6401 for horizontal installation position
Material: Metal
Befestigungswinkel für DD/DDS,

Air pressure

Metal, S-shape, type 6402 for vertical installation position
Material: Metal
Befestigungswinkel für DD/DDS,

Air pressure

Kunststoff, L-Form, Typ 6481 aufschnappbar für horizontale Einbaulage
Befestigungswinkel für DD/DDS,

Air pressure

Kunststoff, S-Form, Typ 6482 aufschnappbar für vertikale Einbaulage
CAB-02

Accessoires

USB cable for OPP-Room for configuring OPP-Room transmitters.
For configuring outputs, controller settings,
display brightness, alarm thresholds (LCD display
color change ), bus settings, etc. Galvanic
isolation included. For use with the OR-C
OPP-Room configuration software (see the download
area of our website).
Data sheet no. 20560
CO2-Alarm Set 1 - Basis-Set

Air quality

1 control center + 1 CO2 sensor + 1 flashing light with buzzer. Incl. accessories.
Compact set (replacement for standard set 1).
Control center and CO2 sensor with large display.
Measuring range: 0 – 30,000 ppm (corresponds to 0
– 3% vol). For simple local monitoring tasks.
Visual and acoustic warning. Wire pre-installed
on connector for short signal paths between
sensor and display unit and fast installation.
Max. distance between control unit and sensor
approx. 10 m. Used for bottle storage, dispensing
systems, kiosks, for example. Not a substitute
for a gas detection system. Power supply: 230V AC
with included plug-in power supply. Optional
accessories: Extension set for CO2 alarm set 2
(item no. 101632) consisting of: 1 CO2 sensor and
1 flashing light with buzzer.
Data sheet no. 14151