Car parks and tunnels
EBR-01 Einbaurahmen
Car parks and tunnels
for TGÜ-BM 3.6 incl. installation material and 1.50 m data cable.
Installation frame for split mounting of the
TGÜ-BM 3.6 on the control cabinet rear wall and
the operating and display unit in the control
cabinet door. Please observe the installation
instructions in data sheet 34120.
Installation frame for split mounting of the
TGÜ-BM 3.6 on the control cabinet rear wall and
the operating and display unit in the control
cabinet door. Please observe the installation
instructions in data sheet 34120.
GMF 4DUO.E/P.CO/LPG.MOD
Car parks and tunnels
DUO-MOD double sensor for carbon monoxide and LPG, measuring range: CO 0 to 300 ppm, LPG 0 to 100 % LEL
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels (only CO sensors). The DUO dual sensor
consists of the two gas measuring sensors CO-Mod
and LPG-Mod. Both sensors differ from the mod
single sensors in the housing designs. These are
designed in such a way that they can be mounted
in line underneath each other. The CO/LPG
measuring cell is suitable for measuring low
concentrations of carbon monoxide or LPG in the
air. Type of gas: Carbon monoxide CO measuring
range: 0 – 300 ppm MAC-value: 30 ppm, relative
gas density: 0.97. Type of gas: Propane gas
measuring range: 0 – 100 % LEL MAC value: 1,000
ppm, relative gas density: 1.56. Housing:
Aluminum gray, IP 44 protection. Dimensions (H x
W x D): 80 x 125 x 57 mm. Gas supply: diffusion.
Output signal: RS485 MOD. Power supply: 12 – 36 V
DC. Long-term drift: 1% per month. Linearity
error: < 2%. Temperature range: -10 °C – +40 °C.
Humidity range: non-condensing. Data sheet 38104
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels (only CO sensors). The DUO dual sensor
consists of the two gas measuring sensors CO-Mod
and LPG-Mod. Both sensors differ from the mod
single sensors in the housing designs. These are
designed in such a way that they can be mounted
in line underneath each other. The CO/LPG
measuring cell is suitable for measuring low
concentrations of carbon monoxide or LPG in the
air. Type of gas: Carbon monoxide CO measuring
range: 0 – 300 ppm MAC-value: 30 ppm, relative
gas density: 0.97. Type of gas: Propane gas
measuring range: 0 – 100 % LEL MAC value: 1,000
ppm, relative gas density: 1.56. Housing:
Aluminum gray, IP 44 protection. Dimensions (H x
W x D): 80 x 125 x 57 mm. Gas supply: diffusion.
Output signal: RS485 MOD. Power supply: 12 – 36 V
DC. Long-term drift: 1% per month. Linearity
error: < 2%. Temperature range: -10 °C – +40 °C.
Humidity range: non-condensing. Data sheet 38104
HT-TGÜ
Car parks and tunnels
Humidity sensor for integration into TGÜ-KM 3.6
2 HT-TGÜ are required for the humidity monitoring
or humidity control function of the TGÜ-KM 3.6.
One of the two sensors is installed in the
underground garage, the other one is installed
outside. Supply voltage 24 V DC. With M16 cable
gland, IP 65 protection plastic housing, sensor
IP20.
Data sheet no. 36300
2 HT-TGÜ are required for the humidity monitoring
or humidity control function of the TGÜ-KM 3.6.
One of the two sensors is installed in the
underground garage, the other one is installed
outside. Supply voltage 24 V DC. With M16 cable
gland, IP 65 protection plastic housing, sensor
IP20.
Data sheet no. 36300
TGÜ-BM 3.6
Car parks and tunnels
Underground garage monitoring unit central in wall-mounted housing.
For monitoring underground garages & tunnels. For
connecting up to 240 CO or NO2 OPP-SOR® gas
measuring sensors type GMF-MOD. 4 alarm zones
integrated. Max. 60 gas measuring sensors per
zone. 4 alarm switching points depending on
average value or actual value. 1 collective fault
output with floating changeover contacts. 7
changeover relay outputs per zone for fan 1+2+3
as well as horn, warning transparency, device
error and BMS. Color LCD TFT display for
operation, alarm and fault messages as well as
for displaying measuring point information such
as gas type and concentration, multi-language
selectable. Operation on the device via 8 touch
keys. Zone-related LED status display. Average
calculation, system clock for data logger
function, self monitoring, bus-monitoring. Data
interface: RS485 Modbus for the connection to
GLT. Ethernet interface for connection to
TCP/IP-based networks. Including timer & optional
humidity monitoring. Necessary accessories for
humidity monitoring: 2 x humidity sensor type
HT-TGÜ. This reduces the maximum number of
connectible gas measuring sensors per zone by 2.
Supply 230 V AC or 24 V DC from UPS system.
Plastic wall housing made of ABS with lid. With
cable glands 17 x M16, 2 x M20 and 1 x M20
dividable screw connection. Protection class: IP
54. Dimensions: 340 x 230 x 112 mm (W x H x D).
Data sheet no. 34120
For monitoring underground garages & tunnels. For
connecting up to 240 CO or NO2 OPP-SOR® gas
measuring sensors type GMF-MOD. 4 alarm zones
integrated. Max. 60 gas measuring sensors per
zone. 4 alarm switching points depending on
average value or actual value. 1 collective fault
output with floating changeover contacts. 7
changeover relay outputs per zone for fan 1+2+3
as well as horn, warning transparency, device
error and BMS. Color LCD TFT display for
operation, alarm and fault messages as well as
for displaying measuring point information such
as gas type and concentration, multi-language
selectable. Operation on the device via 8 touch
keys. Zone-related LED status display. Average
calculation, system clock for data logger
function, self monitoring, bus-monitoring. Data
interface: RS485 Modbus for the connection to
GLT. Ethernet interface for connection to
TCP/IP-based networks. Including timer & optional
humidity monitoring. Necessary accessories for
humidity monitoring: 2 x humidity sensor type
HT-TGÜ. This reduces the maximum number of
connectible gas measuring sensors per zone by 2.
Supply 230 V AC or 24 V DC from UPS system.
Plastic wall housing made of ABS with lid. With
cable glands 17 x M16, 2 x M20 and 1 x M20
dividable screw connection. Protection class: IP
54. Dimensions: 340 x 230 x 112 mm (W x H x D).
Data sheet no. 34120
TGÜ-KM 3.6
Car parks and tunnels
Underground garage monitoring unit Compact device in wall-mounted housing. BUS technology.
TÜV certified to DIN EN 50545-1 in accordance with
VDI 2053-1 and SWKI VA 103-1 (Switzerland) for
monitoring underground garages & tunnels. For
connecting up to 24 CO or NO2 OPP-SOR® gas
measuring sensors type GMF-MOD. Operation &
monitoring via built-in display. With sensor
keypad, menu-driven and 5 different colored LEDs.
Modbus output RS 485 for connection to the
building management system. Up to 6 languages
selectable. 6 relay outputs, potential-free,
partially programmable in cycles. Input for
unlocking the horn. Including timer & optional
humidity monitoring. Necessary accessories for
humidity monitoring: 2 x humidity sensor type
HT-TGÜ. This reduces the maximum number of
connectible gas measuring sensors by 2. Supply
230 V AC or 24 V DC from UPS system. Plastic wall
housing made of plastic ABS. With cable glands
M16. Protection class: IP 65. Dimensions: 200 x
145 x 87 mm (W x H x D).
Data sheet no. 34118
TÜV certified to DIN EN 50545-1 in accordance with
VDI 2053-1 and SWKI VA 103-1 (Switzerland) for
monitoring underground garages & tunnels. For
connecting up to 24 CO or NO2 OPP-SOR® gas
measuring sensors type GMF-MOD. Operation &
monitoring via built-in display. With sensor
keypad, menu-driven and 5 different colored LEDs.
Modbus output RS 485 for connection to the
building management system. Up to 6 languages
selectable. 6 relay outputs, potential-free,
partially programmable in cycles. Input for
unlocking the horn. Including timer & optional
humidity monitoring. Necessary accessories for
humidity monitoring: 2 x humidity sensor type
HT-TGÜ. This reduces the maximum number of
connectible gas measuring sensors by 2. Supply
230 V AC or 24 V DC from UPS system. Plastic wall
housing made of plastic ABS. With cable glands
M16. Protection class: IP 65. Dimensions: 200 x
145 x 87 mm (W x H x D).
Data sheet no. 34118